Please enable JavaScript to view this site.

The File — Open with verification command searches for and fixes errors in the file being opened. In some cases, it lets you to:

Open a KOMPAS document that cannot be opened in the usual way (the message "Invalid file structure..." is displayed, or no message appears, but abnormal termination occurs in KOMPAS-3D).

Fix a model with operations without history that is incorrectly – without some faces or ribs – displayed, highlighted, or projected into a drawing. To solve this problem, before invoking the Open with verification command, it is necessary to create the file Kompas.ini, and within it — the [RestoreShells] section with the RestoreName key. Details...

Correct the following errors in KOMPAS documents:

related to matings of components in assembly:

 

matings cannot be created,

matings cannot be deleted,

matings are not displayed or displayed incorrectly in the Model Tree,

associated with designations and names:

it is impossible to set the designation and name for the model,

 

dependent versions have the same designation due to a match of fill numbers,

 

the designation of the component in the Tree is incorrect,

 

the names of the standard products are not displayed,

 

cannot be derived from the source of component designations and names, including local components,

 

designations and names of solids are lost; in this case, recovery is not possible - after opening with verification, the solids are given the default names Solid1, Solid2, etc.

 

there are no user defined designations; in this case, they cannot be restored: after opening with verification, default numbers are assigned to versions,

 

related to the sketches:

is incorrectly displayed in the Tree to determine how well defined the sketch is,

 

you can't select a sketch to perform an operation,

 

failure of trying to edit sketch in component.

 

failure to call the command Remove invalid projection links,

 

related to displaying model objects:

the objects selected in the Tree are incorrectly highlighted in the model window.

 

objects in the Tree do not exist in the graphical area,

 

objects in the graphic area do not exist in the Tree,

 

related to the setup of the graphical document:

incomplete list of objects for which auto-sorting is available in the auto-sorting setting dialog,

 

incomplete list of arrows in the linear dimensions arrow filter configuration dialog,

 

related to the rendering of the graphical document:

the text is condensed even though the Width parameter value is 100%,

 

when you wrap the technical requirements text to next, the part of the link found on the other line is black instead of dark blue,

 

plain text between two adjacent links in technical requirements is dark blue as opposed to black,

 

the objects are missing in the graphical area because their coordinate position values are out of bounds (by opening with verification, the incorrect coordinates are changed to 0 and the objects are visible),

 

incorrect display of bounding pads,

 

related to the drawing technical requirements:

technical requirements cannot be displayed or edited in the drawing,

 

an error occurred while trying to edit, place, or synchronize technical requirements,

 

the inability to pass on the sketch change from the master version to the dependent one,

 

the "Lost Link to variable" error in the model without specifying the variable name,

 

the impossibility of saving information about the selected detailing in the drawing,

 

impossibility to export a graphical document to DXF or DWG format,

 

there are several current layers or multiple layers with the same number,

 

 incorrect position of texts and/or designations after zooming in or when inserting an image from another drawing to a different zoom view (in the latter case, open with verification and save the source drawing).

Once a model is opened with verification, it generally needs to be rebuilt; loss of links between objects is possible in this process.

Before you open files with verification, we recommend the following:

create copies of files,

remove protection from files protected with KOMPAS Protection.

© ASCON-Design systems, LLC (Russia), 2024. All rights reserved.