Setting Parameters of Majority Surface Finish |
Scroll |
A special process is used to set the parameters of majority surface finish.
All settings performed in the process of configuring the majority surface finish are displayed on the phantom in the upper right corner in the graphic range of the model.
Step-by-step instructions
1.Select the sign type by clicking the required button in the Machining Method group:
Not Specified,
Delete Material Layer,
Keep Material Layer.
2.Insert a text box for the designation. To do this, click Text field on the Parameter Panel or the text field on the designation phantom. This will start the Add Text subprocess.
During this subprocess, the text field on the of the designation phantom is available for editing. Double clicking this field opens the user menu containing the surface finish parameters Ra, Rz, Rmax and their values.
After this subprocess is closed, the system will return to the process of setting the of the designation parameters.
3.Activate the Sign in Parentheses option if you need to add a sign in brackets to the majority surface finish.
4.If necessary, set the color of the sign using the Displaying group of controls in the Properties section. Details...
5.To complete configuration, click Create Object button
.
The Finish button
allows you to cancel creation of the of the designation.