To enable and configure zone partitioning of the current drawing, see Zoning of setting dialog box. To access the section, invoke the Settings — Parameters...
and in the dialog box that appears, select Current document — Document parameters — Zoning.
The dialog box allows to activate the mode of dividing the drawing into zones, to set the dimensions of these zones and their designations.
Controls of the table name setting section
Element |
Setting description |
||||||||||||||||||||||||||||||
Divide into zones |
The option allows you to activate sheet partitioning into zones and customize partitioning parameters. By default, the option is disabled and all dialog controls are unavailable. |
— |
|||||||||||||||||||||||||||||
Zoning rectangle |
Fields for specifying zone height and width values. The values can be entered manually or selected from a list. When partitioning a sheet into zones, the orientation of the partitioning rectangle is ignored: the sheet side is divided by the length of the side of the rectangle that fits the maximum number of times within the length of that sheet side. |
— |
|||||||||||||||||||||||||||||
Use vertical marks/ Use horizontal marks |
The options control the vertical/horizontal positioning of zone labels on the drawing sheet. When the options are enabled, the corresponding items for setting the zone marking parameters become available. |
— |
|||||||||||||||||||||||||||||
Text type |
The drop-down list allows you to select symbols for zone designation (Arabic or Roman numerals, letters of the Russian or Latin alphabet). |
— |
|||||||||||||||||||||||||||||
Start from |
The field allows you to enter a digit or letter number with which the series of designations will begin. |
— |
|||||||||||||||||||||||||||||
Direction |
The drop-down list allows you to select the direction of labeling Bottom up, Top down/ Left to right, Right to left. |
— |
|||||||||||||||||||||||||||||
Line type |
The drop-down list allows you to select the type of line for drawing zone boundaries. The line appearance is displayed in the View field. |
— |
|||||||||||||||||||||||||||||
Width of the zone designation field, mm |
The drop-down list allows you to select the zone designation field width value (in millimeters). |
— |
|||||||||||||||||||||||||||||
Zone designation field width |
The option allows to place the zone designation field outside the inner frame of the sheet. If the option is disabled, the zone designation field will be located inside the inner frame. |
— |
|||||||||||||||||||||||||||||
The text is always horizontal |
The option allows all zone designation symbols to be placed horizontally. |
— |
|||||||||||||||||||||||||||||
Font parameters |
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
|
|
|
||||||||||||||||||||||||||||
When the settings are complete, click the dialog box Apply and close. To exit the dialog without changing the settings, click Cancel.
The zone partitioning settings are stored in the drawing itself and are not changed when the drawing is transferred to another workstation.