Please enable JavaScript to view this site.

This section describes the column parameter settings for the following tables:

tables of the reports — dialog Report Style,

tables of the versions — dialog Table of versions parameters,

tables of the report by array with table of modifiable variables — dialog Array report table parameters.

Parameters are set for each column of the table displayed in the dialog settings window. To the left of the window, there is the name of the customized parameter, its value is set in the corresponding cell of the column.

General settings elements


The element

Description


Property

Property names field. Select a property option from the list in which all local properties of the document are available.

If the desired property is not listed, click the Settings... line. A dialog will appear on the screen allowing you to customize the list and select a property from the property library.

In this dialog perform the following steps.

To add a property to the list from the library, connect the library on the tab Property Libraries. Work in dialog is similar to Property List Settings for new documents.

To customize the list, enable the options next to the desired properties in the tab Properties. The selected property in the dialog automatically becomes the selected property in the report column.

When configuring an array report table, this field displays the name of the array instance parameter (e.g., coordinates of points that specify instance positions, variable names). Choose parameter name from the list. The list of instance parameters corresponds to columns of the tables of modifiable variables In the selected array.


Column name

The row of column headers in the table. For example, the property Weight may have a title in the report Weight, kg.

By default, the column header is the same as the property name.

Enter the desired column heading.


Measurement Unit

Field units of property. Select the desired unit of measure from the list.


Rounding

A field in which you can specify to which sign the value of a property with a real data type should be rounded off in a report.

The maximum number of characters is 6.


Decimal Places

A field in which you can set the number of decimal places for displaying property values with a real data type. The maximum number of characters is 6.

The number of decimal places in the values of maximum deviations automatically determined by the deviation with the maximum number of characters (determination is made for each cell of the table separately).


Maximum deviations can be displayed in the table of versions and in the table of the report by array.


Column width, mm

The column width field in the table. Enter an integer number in millimeters.


Alignment

A field with a list from which you can select an option to align the text in the cells of the column, except for the header cell.

When selecting the option Style, the text in the cell is aligned according to the parameters set in The dialog for setting text parameters document in which a table is placed.


Wrap

Option allowing displaying cell contents in one or several lines (designations, numbers, text), whose length exceeds the width of the column.

If this option is enabled, the text or group of characters separated by a space can be moved to a new line. If the option is disabled, the contents of the cell are displayed in one line with the narrowing of characters.


Merge cells

The option allows you to combine successive cells in a column if the contents of these cells are the same, i.e. if the displayed property has the same value in several consecutive lines.

Additional elements of the table settings


The element

Description


Display

Option allowing enable/disable showing a column in a report. If this option is enabled, the column is displayed in the report. If the option is disabled, the column is not displayed.


Sorting

A field that displays the sorting options.

If the field is empty, then the sorting by this property is not performed.

If there is text in the field, this property participates in sorting. For example, the text Priority 1 “A-Z” indicates that the property has the highest priority and the values of this property will be arranged in alphabetical order in the report.

A click on the field Sorting any of the columns brings up a dialog in which you can Configure the data sorting parameters.


Grouping

A field with a list from which you can select parameters of data display in a grouped report.

The desired option is selected for each property.

To group the report by a certain property, select the Coincidence option for it — rows of objects having identical values of this property will be replaced by a single resultant row. The remaining options determine how the property values will be displayed in the resulting row.

More information about configuring grouping...


Detailing

This button opens a dialog in which you can Configure the design parameters of the report..

Additional configuration elements of the table of versions and the array report table


The element

Description


Value format

A field with a list that allows to choose how the value of an array instance property or parameter is displayed in the table.

For example, in the execution table for the Designation property the following display options are available:

Full designations,

Only version numbers. Selecting the required option for this property is equivalent to enabling the Full symbols options on the Parameter Panel.