You can set the position designations for parts and assemblies in the Position designation section of the setting dialog box.

To access the section, call the command Settings — Parameters... and in the dialog box that appears, select Current document — Conventional symbols — Position designation.

The dialog box allows you to configure the geometric parameters of designations, shape and text parameters, and select the option of drawing arrows of position designations. Using the arrow filter you can specify which arrows will be available when creating position symbols, set their sequence in the list and select the default option.

Controls of the position designation setting section


Element

Setting description

№ subgroup


Arrows

The drop-down list allows you to select the option of drawing arrows of position designations. The following options are available:

To fill with black,

Do not black out.

1.1

Geometric parameters


Arrow length, mm

Arrow angle, deg

Distance from landing to text, mm

Distance from the beginning of the landing to the text, mm

Landing overhang, mm

Indent in front of the text behind the landing, mm

Group of fields for specifying values of geometrical parameters of position designations. The parameter value is entered in the field. Click on the icon allows you to select a value from the drop-down list.

1.1

Form parameters


Form type

The drop-down list allows you to select the desired type of item designation form. The following options are available:

Plain text,

Open text,

Circle,

Hexagon,

Circle with separator.

2.1


Form size

The field is used to specify the size of item designations with the form type «Circle», «Hexagon», «Circle with separator». Size value (in millimeters) can be set manually or selected from a list.

For a form of the type «Circle» this value defines the diameter, for a shape of type «Hexagon» — diameter of the inscribed circle, for the shape type «Circle with separator» — radius.

If the form size is too small, the position numbers may extend beyond the icons. To change the font height of the position numbers, use the controls of the group Text parameters (see description below).

1.1


Location of the designation

The drop-down list allows you to select the layout of item designations containing multiple item numbers. The following options are available:

Horizontally — item numbers will be arranged in a row,

Vertically — item numbers will be arranged in a column.

2.1


Form a landing

The option controls the drawing of the landing of the positioning guide line.

For items with the «Simple text» form type, the landing is a regular leader landing with text above it. For other form types, the landing is — is a segment connecting the text to the leader.

Examples of item designation form types are given in the section Position designation parameters.

2.1

Text parameters


Font

The drop-down list allows you to select the desired font. The list contains all fonts connected to the OS.

2.2


Different from default font

The option allows you to set the font to match or differ from the document's default font.

If the option is disabled, the font always matches the default.

2.2


Style

The elements group allows you to set the regular, italic or thickened symbol layout.

2.2


Color

A field that displays the current color of the symbol. To change the color, click in the field.

2.2


Height, mm

The field allows you to enter a character height value (in millimeters) or select this value from the drop-down list. The manually entered value is added to the list and saved for the duration of the session KOMPAS-3D.

2.2


Width, %

The field allows you to enter a character width value or select the value from the drop-down list. A manually entered value is added to the list and saved for the duration of the session KOMPAS-3D.

2.2


Preview

The preview window shows the appearance of the text. This allows you to visually evaluate the changes made.


Line spacing, mm

The field allows you to enter a value for the distance between lines of text.

2.2

Arrow filter

 

Arrow filter

The list contains names and samples of all arrow types available in the system for leaders of position designations.

To the right of arrow names there are options that allow to enable/disable display of corresponding arrow types in the Arrow list in the Parameter panel when working with leaders. Those arrows which names have options enabled are available in the document: they are included in the list from which the arrow type is selected when creating an object.

The No arrow option does not have an option. It cannot be disabled, it is always available when creating dimensions in documents.

The option in the list header allows you to enable or disable the display of all arrow types in the list at once. The option can be in one of three states:

enabled  — all options in the list are enabled (all arrow types present in the list are available in the Parameter panel),

unefined  — the list contains both enabled and disabled options (arrow views with enabled options are shown in the Parameter panel, while those with disabled options are not.),

disabled  — all options in the list are disabled (only the view is available in the Parameter panel No arrow, other arrows in the list are unavailable).

If the state of an option is not defined, clicking on the option will disable it, the next click will enable it.

1.2

Move up

Move down

The buttons allow you to customize the order of arrows in the list.

To change the position of an arrow, select it and press the required button. The selected arrow will move one position in the specified direction.

The order of arrows set in this dialog box is passed to the list from which the arrow type is selected when creating an object.

If the first arrow or the first arrows in the list are disabled, the first enabled arrow is the default one. To speed up the creation of objects in the document, it is recommended to put the arrow type that is used most often on the first position, followed by the other arrow types in descending order of their frequency of use.

1.2

After completing the settings, click the dialog box Apply and close. To exit the dialog box without changing the settings, click Cancel.